What is JEPostOffice?

JEPost office is an 'add on' program to allow users to send, faxes (with WinFax), Cedex, Edifact and 322 messages as e-mail attachments. It was the first of the CDS2100 range of systems.

Typically The JEPostOffice Set-up program is loaded on the Server at F:\JEI\JEPO.
On the workstation that the program is to be installed choose Start and Run and then Browse to F:\JEI\Jepo\JEPO1-5Setup.EXE which will install the program.
After installing, but before you can open the JEPostOffice, it will require a license file.
Copy F:\JEI\Jepo\JE.lic to C:\Program Files\Jei\JEPostOffice.

You should now be able to open the JEPostOffice. Choose File and Options. On the General tab:
- Ensure the processing options you require are checked on the WinFax tab:
- Ensure that the File Folder is set to F:\JEI\FAXES
- Ensure the Omit Date is checked.
- Ensure that the Use COM Interface is checked, on the Email tab:
- Ensure the File Folder is set to F:\JEI\EMAIL.
- Ensure the Microsoft Outlook is checked, on the Cedex tab:
- Ensure the File Folder is set to F:\JEI\CEDEX.
- Ensure the Sender ID is filled in.

The CDS49 is currently set to work with WinBridge and output files to C:\COMMERCE.
If you wish to switch it to the JEPostOffice the in the CDS49 Maint Set-up, change the EDI DIRECTORY to F:\JEI\CEDEX

  Data Import File for transferring from your existing system to CDS49.

It should be a comma separated values file, named BATCHENT.CSV.

One line per record. The fields in each record are:

Max Size
1.Container No 11Mandatory - Prefix+Number+CheckDigit
2.Size2Mandatory - ISO Size Code - Must exist in CDS49
3.Type2Mandatory - ISO Type Code – Must exist in CDS49
4.Customer Code6 Mandatory - Must exist in CDS49
5.Customer Name12
6.Condition In3Condition of unit at In Gate - SND or DAM (Default)
7.Date Inmm/dd/yyyy Mandatory
8.Estimate Datemm/dd/yyyy
9.Auth Datemm/dd/yyyy
10.Repair Datemm/dd/yyyy
11.Available Datemm/dd/yyyy
12.Notes70Upper Case
13.Status30Upper Case - Must exist in CDS49
14.Companion N11
15.Ground Datemm/dd/yyyy

The dates determine if status is AWAIT ESTIMATE, AWAIT AUTH, AWAIT REPAIR, or AVAILABLE. Any other status can be put in Status field, so long as they already exist in CDS49.

 

I was inputting the customer address and there are some companies that i have to put a second address. Invoice could get billed to address#1 or to Address #2. We were imputing the second address on the right side second Box. But it's not taking as a second address it's combining both Addresses.

Can you please tell me were do i enter the second address.

On Page 1 of the Customer screen, the 6 INV ADDRESS fields are for the Invoice Address. On Page 3 of the Customer screen the ADDRESS2 fields are used for information and/or a second Invoice Address.

For Repair Invoices *only* INV ADDRESS is used.
For Storage & Handling Invoices INV ADDRESS or ADDRESS2 is used depending on whether ADDRESS (on Page 4) is set to 1 or 2.

For Manual Invoices INV ADDRESS or ADDRESS2 is used depending on whether ADDRESS (on Manual Invoice Screen) is set to 1 or 2.

  When I try to print a report from my computer, I get the following message before the system completely shuts down. "Moverpt Table is damaged"

On the workstation where you have the problem do Reports, PrivRestore. This will restore any of the temporary report tables including the Moverpt and fix the problem.

  Can we input estimates using CEDEC codes?

As you have estimates already in the system, we cannot replace your code set. You would need to add another code using the Cedex Code for every code you have.

You can do this in the component screen by pressing Insert and filling in the Cedex Code in the COMPONENT field and then press F7 in each of the other fields. The F7 key copies what is on the record that was present before inserting the new record. Test it by doing it on one component and then using that component on an estimate. Don't forget that after adding a component record you need to run the Prep option on the Lookup Sub Menu before the component is available for use in estimates.

 

I just got he the same MasterView lockout error as before. There are two units in the system with wrong numbers.
ICSZ163633 Should be ICSZ163623
HDMZ402774 Should be HMDZ402874
It said Lockout by Window_1

There are locks present on records which should have been closed. This happens when the CDS49 is not exitted as it should, either by rebooting the machine or an error that throws you out of the system.

What you need to do is make sure everyone is out of the system and then shutdown and restart the server. Afer this is done, and before anyone goes back into the system, you need to delete the .LCK and . NET files. From your workstation you should delete I:\CDS49\PDOXUSRS.NET and I:\CDS49\*.NET This should resolve the problem.

  Please advise if the invoice rolls over to the Peachtree soft on its own, Or do we manually have to put it in using the link.

You export from cds49 to Peachtree (push) Peachtree imports (pull)

  Also, with computers changing daily, if there is an upgrade how do you and I handle this?

You would collect it from our web site and it would automatically install itself.

  Is there any way to get our address and phone as well as the customers address on the monthly storage bill. It's not a big deal I just thought there might be a setting in Set-up or something.

To put your address on the Invoices it must be set-up in the Set-up Screen (Maint, Set-up) in the ADDRESS fields under the COMPANY Names. You should also have the HEADED INVS & ESTS set to N, if you want the Company Name and Address to appear on the Invoices.

 

As you are aware, after transferring the Evans system to the new NT Workstations and network, we are experiencing a long delay in the printing Of estimates. I believe we did some preliminary troubleshooting but the Problem still exists. I am asking for your assistance in working with

S and his group to try and resolve the issue. I know that when the Evans system was set up at JS, a custom batch job was placed on The workstation desktop to map a drive to the printer. I don't know if Something similar was done at the terminal or needs to be done for the

System to recognise the printer. I believe there was an issue from within The application as to whether DOS or Windows was commanding which printer to use.

I have put an icon on MNR3 to access the JEI CDS49. Please ask F to go into the JEI CDS49 on MNR3 (The Server) and try printing an estimate. This is only for testing purposes to establish whether the problem is a printer Or network issue. I do not intend to leave access to the JEI CDS49 on MNR3.

If the speed of the printing dramatically increases (on MNR3), then it may not be a printing issue.

  I spoke to f about the improved printing time. F told me the "print test" sheet that was sent to the printer indeed printed fast, however all other printing still takes 55 seconds from F's work station and 30 seconds from T's work station (T's work station is hooked up directly to the printer ). During this lag time, the workstations will not accept commands which results in either the service writer or t to "stand-by" to make their next entry.

I have looked at the printer set-up, and it looks okay. I spoke with F, one of the surveyors, yesterday and he says it had started printing quickly, but there was a problem with the font size. I believe the font size is set on the panel of the printer itself, and it is a matter of testing the different fonts to find the best choice. This cannot be done remotely, but needs to be done on site.

  I pulled up a work order and pressed the f10 key to print. The Response from the time it took to press f10 to the time the printer started To print the work order was "3 seconds". Please advise next step

I take it from your reply that printing on MNR3 is fast, compared with MNR4 & MNR5.This means that the problem is likely to do with the network, not the Printer. I know that earlier this year an additional workstation (MNR1) was added at JS and it suffered from speed problems, which proved difficult to pinpoint, but was resolved by changing the network card. I

Don't know how the network is routed at the Port, that could also be a possibility. I hope this is of help.

  We were trying to load TPC with the tariffs we have entered. When we upload and go to F drive, only old tariffs show on drive. How do we load new tariffs into TPC??? Are we missing a step after we complete the tariffs???

1) Are you running the Prep option in Lookup section?
2) If you are do the new tariffs appearing on the simulator?
3) When you upload PC to TouchPC using PCLink, can you see files with the extension .tar being transferred?

  Please check these 2 units: xxxx2446483 and xxxx8229588 in our system. They are lessor approved but we can not get them to print on depot activity for Nov 6.

I logged on this morning and checked out xxxx2446483 and xxxx8229588. They both have the same problem. The CUST APPR AMOUNT was 0.00 and the LESSEE AP AMOUNT was filled in. For the Customer to get the approval, the amount must be greater than 0.00. Please change the CUST APPR AMOUNT to the amount approved and the LESSEE AP AMOUNT to 0.00 and they should appear on the depot activity for 6th November.

 

Please check following units: CLHU2443329, xxxx4166692, xxxx8220929, xxxx8221442.

The above 4 units do not show as lessee approval on depot activity. Also, xxxx2443329 is customer approved and that does not show on depot activity either.

I checked out the units for approval. They should have appeared on the daily movements for 9 November. Your data was correct. I checked the program and found an error in a recent change we had made. I have corrected it and the units do now appear on the daily movements for the 9th November. Thanks to you for checking, so that I was able to find the error.

  EAGLE2 with NT

The Eagle2 programs have been updated. Due to a quirk of NT, it is not possible to upload or download the Eagles from within the CDS49.

We have already set-up an Eagle download shortcut on one of the desktops.
You now need to set-up an Eagle Upload shortcut.
On the desktop, right click and open a new shortcut.
The command line is F:\JEI\CDS49\TPCUP.BAT
When running this shortcut it opens PCLink using COM1 at 115.2, to upload most of the files.
When you exit PCLink it opens again but for uploading the tariffs, again using COM1 at 115.2.

  On gate movement screen entered inbound. After info is saved, how can we edit? Pressed F3-didn't work?

On the Gate screen, once a container has been released from the system you cannot change the gate information. On the Gate screen, once a container has been accepted into the system you cannot change the gate information. This is because it is a record of the gate interchange. However, details relating to the container can be changed on the Master Viewing Screen. From the Gate Movements screen, press F1 to go to the Master Viewing Screen. Find the Container you wish to change and then move the cursor to the data field you wish to change.

Now press Ctrl+Home and it will let you change that piece of data. The system doesn't let you change all the data fields, but most are accessible in this way. Some data fields relating to the Survey such as Size and ISO Type can only be changed in the Survey screen, rather than the Master Viewing screen.

On gate movement screen, entered unit then deleted-but could not re-enter unit. During deletion got following message: run error-expecting value of date type.

This is because it is a record of the gate interchange. However, you can edit the data on the Master Viewing Screen, using the Crtl+Home as above. In addition, on the Master Viewing screen, there is an option F6 UndoOut that undoes an Out Movement.

  For unit CRLU913658-changed to available on survey screen-entered dates 6/22/00 in pg2 of 2 on "available" & "repaired" yet when we went to outgate-container showed awaiting repair. Put in available status again and it showed up on daily activity?

I can't tell what went wrong for CRLU 913658, but filling in the Available Date should change the Status to AVAILABLE. Please test this on another container and let me know if it is not working. Dates should be input including the century (6/22/2000).

  We have 2 mailing addresses for several customers. (Certain invoices to each address) Where do I enter second address on customer info?

The two invoice addresses on the Customer details screen are on Page 1 for 4 (INV ADDRESS) and Page 3 of 4 (ADDRESS2). Repair invoices always use the INV ADDRESS. Storage and Handling Invoices can use either the INV ADDRESS or ADDRESS2 depending on whether you set ADDRESS (on Page 4 of 4) to 1 or 2. Manual Invoices can use either address.

Repair estimates can also be billed to separate customers depending on the authorisation on the estimate.

  CDS49 Enhancements

We have updated your CDS49 system with some enhancements. Please can you ensure that each CDS49 workstation does a 'Reports, PrivRestore' to update them.

The enhancements include:

1) Ability to select Surveyor on Survey Request Report (Reports, Repair, Surv).

2) Outstanding Acceptance Report (Reports, Daily, Accepts).

3) Export of Invoices to Peachtree Accounts Package (ImpExp, Export, and InvII).

4) Filename including drive and directory can be inputted in ACCOUNT FILENAME on Page three of Set-up Screen (Maint, Set-up).

5)Container Location List listing units in number order (Reports, Stock, List3).

6) Daily Movement Faxes and Reports to show Surveyed as well as Approved units. This is based on the use of Cedex status codes in the APPR STATUS fields on page 2 of Survey screen. E - Lessee/User Surveyed, L - Lessor/Owner Surveyed, G - Lessee/User Surveyed & Auth, H - Lessor/Owner Surveyed & Auth, Any other code is treated as Approved.

7) Stock Report and Fax (#6) to include MADE BY for use with GESeaco types.

8) Haulier lookup on Eagle and Gate screens (Lookups, More, Haulier).

9) Awaiting Auth & Repair Status Report to show approvals status (Reports, Repair, Await).

10) F2 FindNo on Master Viewing Screen will also search for Previous Container No.

11)When an approval is added to the Survey record it is automatically flagged as a 'Revised record', given a Revision Number and Revision Date. The Revision Date is the date of input. For the approval to appear on the daily movement report, both the Revision Date and approval Date should be the same as the Movement Date.

  We're looking into a new printer, as you know. Need to know if J.Evans System passes print job to windows control? Does it use Windows drivers?

The John Evans System sends all output to LPT1. It does not use the Windows drivers. It does not utilise the Windows API. Windows captures any output to LPT1 and redirects it to the printer. Windows may utilise the printer driver at this point, but that is decided by the printer driver.

  We're using customer: DUMB for practice purposes. Can I make equipment under this customer available so I can try the invoice formats without rolling over any invoice info? Would this create any other problems?

The invoicing of your DUMB customer can be done separately. For Storage and Handling you can select the Customer to Invoice. For Repair Invoices you can select individual containers to invoice or the Invoice Code. The Invoice Code is just a code to group the invoicing of particular customers together. If you set the INV CODE on page 2 of the Customer screen to DB for the DUMB customer, and then run the repair invoices and input DB for the Invoice Code, then only the DUMB customer should be selected. The only overlap with other customers is the Invoice, No which is a sequential number. You can, however, set this before and after invoicing (see Maint, Inv).

  Tried printing reports, and report does not show survey approvals.

I logged on this morning to check, and found that there was N in the FIN field of both estimates (Page 1 of Survey screen). This tells the program that the estimate is not finished and should be ignored. I removed the N for both TRIU1570551 and TTNU2222411 and ran the Movement Report for 20-Sep-2000 and the Survey Approval sections appeared on the report.

Please make sure that you don't put anything in the FIN field, unless you want the system to ignore the estimate.

When an approval is added to the Survey record it is automatically flagged as a Revised record, given a Revision Number and Revision Date. The Revision Date is the date of input.
For the approval to appear on the daily movement report, both the Revision Date and Approval Date should be the same as the Movement Date.

  Are you able to change the default status from "Damaged" to "Available" for some customer numbers and not others? Hyundai, the customer we are entering now, almost always has "Available" or AV units. I understand the reasoning behind defaulting to "Damaged" but for Hyundai we'd like it to default to "AV"? Is that possible?

The default status in the system is AWAIT ESTIMATE, which cannot be changed. The default notification to your customers on the Daily Movement reports and faxes is either IN DAMAGED or IN. This you can set in the Customer screen, Page 1 in the field IN STATUS.

  I was curious as to why a unit that has just been entered is automatically entered as "Damaged"? Today I had a chassis that came in and when right back out and it said "Awaiting Estimate" when I outbound it? Why is that?

When a unit comes into the yard its default Condition In is Damaged, and default Status is Awaiting Estimate. The unit is then inspected. If it is found to be sound then its status is changed to Available which in turn changes the Condition In to Available. You can make a unit Available by using the F1 Status on the Master Viewing Screen. When a unit is damaged, a repair estimate is needed. It is important that your customer is not notified that a unit is sound and available when it is not, and to prevent damaged units from leaving the yard.

  The client we chose to start with is Hyundai and when we EDI the Trucker data to them it needs to be in 4 letter codes, not the full name. Examples are YARD for Yards Trucking, FACA for FAR Trucking, and LERE For Leight Trucking.

The 4 character EDI codes for Hyundai can be put in the Haulier Lookup table (see Lookup, More, Haulier). They would then be available on the Gate screen using the F1 Lookup key in the Haulier fields. The first 4 character must be for the codes but you can utilise the full 10 characters of the field, as I will only take the first four when creating the EDI message.

  Can we get the "Load" field to automatically populate to "E" considering we only deal with Empty Units?

You would only need to fill in the E for Empty or F for Full if you have both. If you have only one type then there is no need to input anything. If you did have both and it defaulted to E then it would lead to a mistake being made.

  The Size and Type Lists have some duplicate entries and do not have some entries we need. How do we alter these lists?

To adjust your size and types, you need to know the following:

Sizes and Types can be changed from the Lookup Sub Menu
The ISO screen allows you to set the different ISO Type Codes.
The Size screen allows you to set what the different Size codes and ISO Type Codes are for each size.
The IsoAsp screen allows you to set the different Aspects for each ISO Type Code
If you add or delete any ISO Type Codes you need to add and remove them in the Size screen and IsoAsp Screen option as well.

After making any changes you will need to run the Lookup Prep option to update all the Lookup tables.

  GESeaco keeps asking me about the stock reconciliation report transmittal. Do you know GESeaco Depot Code for your depot?

If you do go to Maint, Set-up, Page 2, GENSTAR DEPOT CODE. Edit (F3) the record and fill in the Depot Code. If you have a particular folder you want the file saving to fill in the GENSTAR DIRECTORY (C:\EMAIL for example). Save (F2) the record and escape to the Main Menu.

Now go to ImpExp, Transfer, and SeaStk. This will prompt you for a Transfer List. Enter Y. If your Depot Code is 44L for example then a file STK_44L.001 will be created in the folder specified by GENSTAR DIRECTORY. If no folder was specified then the file is created in the CDS49 folder.

The .001 extension is a counter and every time the program is run it is incremented 002, 003 etc. So don't worry if it is not .001 You can open this file using Notepad or you can attach it to an email and send to GESeaco.

  I am trying to set up another TPC and can not do it. I follow the instructions in the user guide. Then I get to (1.714) the files that require on the TPC, they are not the same in the screen so I don't know which ones I need?

Do you know which port the TouchPC is connected to at the back of your computer? It is usually either COM1 or COM2. Once you know this, you will need to check the settings in the Properties of the TouchPC Download shortcut on your desktop. To do this:

Right click on the TouchPC Download icon
Choose Properties
Choose Shortcut and look for the Target line
There should be text something like C:\PRIV\TPCDLOAD.BAT -c1
The important bit is the -c1 which tells the system that the TouchPC is connected to COM1. -C2 would tell the system that the TouchPC is connected to COM2.

Once the -c setting is set to the correct port, press the OK and try the shortcut.

If this doesn't sort the problem, you will need to tell me which port the TouchPC is connected to and what the Target line is in the shortcut. It is OK if you don't have EPRINT.EXE, EVIEW.EXE, COMP.DAT, IMP.DAT as they are not required for your particular system. Ignore the PARADOX, PCLINK, and PDOXUSRS, as these MUST not be uploaded to the TouchPC.

Are you using the Shortcut on the desktop that John set-up? If you are then you need to set the COM port to 1 or 2 depending on which port the TouchPC is connected to. You also need to make sure that the BAUD RATE is the same on the Workstation as the TouchPC.

Sorry, it is a bit misleading; the manual has not been updated yet with the new program for the TouchPC. The files for the Eagle TouchPC are:

EAGLE2.EXE
EDEL.EXE
EPRINT.EXE
EVIEW.EXE
EXTRN.EXE
SEND
CONDAT.DAT
COMP.DAT
LOCATION.DAT
HELP.DAT
IMP.DAT
PRINT.DAT
ETRANS.BAT
*.TAR --- Any file with a .TAR extension
CUSTOMER.DAT

If any files are missing, don't worry, they may not be required for your particular set-up.

  In the tariff screen how do we know which tariff is in inch or cmt?

You should decide whether you will work in inches or centimetres and then have only tariffs for that measurement. In other words the whole system should be in inches or centimetre, but not both. It can be both but it is much easier if there is only one measurement.

To tell which Tariff is which you will have to look at a few records which have CALC TYPES of L (Length). Inches usually have LIMITS and INCREMENTS of 6, or 12, or 24. Centimetres usually have LIMITS and INCREMENTS of 15, or 30, or 60, or 90 and if the component is the full length of the container they have LIMITS of 600 and 1200.

  In tariff screen there is a field that say's unit of measure, can you explain what this means?

The Tariff's UNIT OF MEASURE is used for the Manual WorkOrders (See Survey, ManWork) which is used for logging work that is done by not estimated for. Such as Roadability Repairs, Reefer Services, etc.

Different jobs that are done can have a price in the tariff and their units of measure are not Centimetres or Inches, but things like Gallon, or Litre. When the job is priced by the tariff the UNIT OF MEASURE from the Tariff appears in the M column next to the UNIT COST.

  On customer screen-what is difference between CD2, CD3 & Cedex?

On the customer screen the CDX identifies customers who use Cedex. The CD2 and CD3 mean that CODE2 or CODE3 for Components, Repairs and Damages are shown on estimates. They do not relate to Cedex.

  We can't enter customer name for 'OutGates'.

The 'CUSTNAME' is for information only, it cannot be entered. It is the CUSTCODE that should be entered.

  To print report of all damaged 40 dry containers for a certain customer; you stated that for ISO type, lower limit should be blank and upper limit ZZ. I tried this & it printed open tops, fridge, etc. How do I get just 40 dry containers?

To select 40 ft dry containers the Size limits would be 40 - 49, and the ISO Type limits would be 10 -10 (for old ISO codes) and G1 - G1 (for new ISO codes). Which means if you use both old and new ISO codes, you would need to run the report twice to select only dry vans.

  How do we delete releases after they are completed or cancelled?

Releases can be Archived (see Maint, Arch, Acceptances & Releases). This archives acceptances and releases based on the END DATE. That is all Acceptances & Releases are archived with an END DATE less than or equal to the date you specify. In order to delete a Release or Acceptance you have to delete all its Containers (F9 on the Release entry screen), by pressing F3 to Edit followed by Delete.

You can follow a similar procedure for Archiving estimates.

  We entered dummy customer of "DUMB" into computer. Customer shows on simulator, but how do we get that info into TPC (hand-held)? Also how can we add prefix of DUMB?

To add a Prefix input it into the Prefix Entry Screen (see Lookup, More, Pref). Following this, run the Prepare Hand-held Codes Program (Lookup, Prep).

Uploading the codes to the Hand-held is usually handled at the end of the Prepare Hand-held Codes Program. However, I think this does not work on NT Workstations.

To upload to the hand-held, do the following. Make sure the TouchPC and the Workstation are connected:

On the TouchPC
Exit the program (The password is NEXIT012).
At the D: > prompt type PCLINK and Enter
Choose Receive.

On the Workstation
Open WindowsNT Explorer
Open the JEI folder on the Server (J:)
Open the CDS49 sub folder.
Open the DDrive sub folder.
Open the program PCLink.exe.
Choose 1 Send File.
Tag all .DAT files by highlighting each file and pressing T.
When all .DAT files have an * showing they are tagged, press Ctrl Enter.
Press the spacebar when you see the message Press Any Key To Start Transfer.

On the TouchPC
Press Receive to start receiving the files.
The TouchPC will prompt you saying a 'File already exists. Do you want to overwrite?'
Reply Y (Yes) each time.
When the transfer is complete, the system will return to the PCLink Menu, choose Receive again.

On the Workstation
Exit PCLink and return to the WindowsNT Explorer.
Go up one level to the CDS49 folder.
Open the Fdrive sub folder.
Open the program PCLink.exe.
Choose 1 Send File.
Tag all .DAT and .TAR files by highlighting each file and pressing T.
When all .DAT and .TAR files have an * showing they are tagged, press Ctrl Enter.
Press the spacebar when you see the message Press Any Key To Start Transfer.

On the TouchPC
Press Receive to start receiving the files.
The TouchPC will prompt you saying a File already exists. Do you want to overwrite? Reply Y (Yes) each time.
When the transfer is complete, it will return to the PCLink Menu
Exit PCLink
Start the program by typing EAGLE2 D:
As soon as the menu appears choose Clear and Delete to delete all data and start with fresh data files. It is essential to do this, to avoid data corruption.

You should now have all the codes uploaded

  On set-up screen; Commerce is listed as CDX Directory. On Commerce version some ISO/size codes do not appear and we cannot use them when we enter our info on Cedex. What do we do?

You should only be using one version of WinBridge, and it should be the latest, which is Sterling Commerce. If it doesn't have all the Size and ISO Codes you require, you will need to speak to Sterling Commerce as they may have an update for you.

  Spoke with Richard Springle at Dixie. Spoke very highly of you & John. I questioned him on ISO codes & Cedex transfer. He stated ISO codes & sizes are entered through TPC & then switched over in system to GESeaco acceptable Cedex codes. Is this switch over done in your system automatically? Does this relate to above?

The Size and Type codes on the TouchPC, in the CDS49 and the WinBridge, should all be ISO codes. The TouchPC, CDS49 and WinBridge do not translate or change the Size and Type codes. The only exceptions are chassis's which do not conform to the ISO standard.

  On ISO Type list what do columns "CDX" & "GEN mean?

In the ISO Type list the CDX refers to the Cedex Code for types of containers. These are CON, REF, TNK, and CHZ for Container, Reefer, Tank and Chassis. These are used within both the CDS49 and WinBridge systems.

The GEN refers to the old Genstar Types such as S, O, F, and R for Standard, Opentop, Flat, and Reefers. These are no longer used.

  On TPC-how do I enter damage size of 4 x 6?

By 4 x 6, do you mean 4inches by 6inches or 4ft x 6ft? The unit of measure you use should be as set on the Customer Details in the UNIT field on Page 2. It is best to use CMT (centimetres) or INH (inches) and use only that unit when inputting the size of repairs.

If the size of repair is unusual and not one commonly used then you can key in that information on the TouchPC in the SIZEXSIZE field. Along with the list of regular sizes there is the option to KEY in the data. Be careful to leave a space before 'x' i.e. 24 x 24 not 24x24.

Please don't use the KEY for Components, Repairs, Damages, Allocations, SZTPs, and CUSTCODE'S. If the size of repair is one commonly used, then you should add it to the SIZES table in the CDS49 (see Lookup, More, Sizes) and then upload it to the TouchPC. John will assist you with this on his next visit.

  On gate movement screen, entered inbound. After info is saved, how can we edit? Pressing F3-didn't work.

-On gate movement screen, entered unit then deleted-but could not re-enter unit. During deletion got following message: run error-expecting value of date type-For unit CRLU913658-changed to available on survey screen-entered dates 6/22/00 in pg2 of 2 on "available" & "repaired" yet when we went to outgate-container showed awaiting repair. Put in available status again and it showed up on daily activity?

On the Gate screen, once a container has been accepted into the system you cannot change the gate information. This is because it is a record of the gate interchange. However, details relating to the container can be changed on the Master Viewing Screen. From the Gate Movements screen, press F1 to go to the Master Viewing Screen. Find the Container you wish to change and then move the cursor to the data field you wish to change.

Now press Ctrl+Home and it will let you change that piece of data. The system doesn't let you change all the data fields, but most are accessible in this way. Some data fields relating to the Survey such as Size and ISO Type can only be changed in the Survey screen, rather than the Master Viewing screen.

I can't tell what went wrong for CRLU 913658, but filling in the Available Date should change the Status to AVAILABLE. Please test this on another container and let me know if it is not working. Dates should be inputted including the century (6/22/2000).

  We have 2 mailing addresses for several customers. (certain invoices to each address) Where do I enter second address on customer info?

The two invoice addresses on the Customer details screen are on Page 1 of 4 (INV ADDRESS) and Page 3 of 4 (ADDRESS2). Repair invoices always use the INV ADDRESS. Storage and Handling Invoices can use either the INV ADDRESS or ADDRESS2 depending on whether you set ADDRESS (on Page 4 of 4) to 1 or 2.

Manual Invoices can use either address. Repair estimates can also be billed to separate customers depending on the authorisation on the estimate.

  Is it possible to delete Customers and Repairers before archiving? They have been used for billing and other operations in the past, but are no longer valid for one reason or another? Ideally, I would like the procedures for deleting a customer or repairer, specifically the sequence at which this should be done.

Repairers can be deleted in the Repairers screen by pressing F3 to edit and then Del to delete.

Customers can be deleted in the Customers screen. First press F9 to get to the storage and handling rates, then F3 to edit and then Del to delete each line item. When all the line items are deleted, press F8 to move to the Customer details and then press F3 to edit and Del to delete.

You should only delete codes from the system if you are sure that you no longer wish to access data regarding them. For instance, if you delete a customer and the system has an invoice for that customer, you will no longer be able to print that invoice.

  John came by yesterday and showed me how to enter components. I entered all of the missing flatrack components and did a PrivRestore. Apparently, the information is not transferring correctly but is correctly saved in the component file.

If the Components are in the system, it maybe that you need to run the Prep codes process (see Lookup, Prep). This prepares any new codes for the Hand-held and also for F1 Lookup menus. When you run this, it will prompt

you to connect the hand-held. Just press Esc when you get the prompt. After running this any new components should appear on the F1 Lookup menus.

  How can I change any information on the batch entries? For example, I entered around 1400 units in the batch entry screen on Monday. I now need to change some of the dates on the units I entered. I went to BATCH, then MASTER, but it only lets me change the status.

You can edit some (but not all) fields in the Master Viewing Screen by moving to the field you want to change and pressing Ctrl+Home.

  I am moving units in on JEI and transferring them to Cedex for transmitting to our customer (CAI). The movements are not transferring over because the units are awaiting estimates. Once I have estimated them they do go through Cedex. This is a problem because we may not have the estimates completed on the day it came in but we do need to let our customers know what came in on that day. Is there a way around this?

On the Customer screen Page 2 of 4 there is a field CDX/GEN GATEIN REQD, change this from Y to N. This is for CAI and any of their Lessee's. By setting it to N it tells the system that the Gate In is not essential for the Estimate and the Estimate is not essential for the Gate In record when transferring to Cedex.

There is one area you need to be aware of, and that is, the status defaults to IN DAMAGED in Cedex. Therefore before transferring to Cedex you must make sure that any sound units have had their status changed to AVAILABLE.

  Somehow the Icons for the Eagle and PCAnywhere connect disappeared from our system (and they say NT is stable). I will set them up again. I need to know the program path and if there are any special settings (memory space, memory size etc.).

The Eagle Download program is TPCDLOAD.BAT and it should be in a directory C:\PRIV or C:\JEI\PRIV, There is also a switch required -C1 or -C2 depending in whether the Eagle connects to COM1 or COM2.

An example the command line would be: C:\JEI\PRIV\TPCDLOAD.BAT -C1.

I don't think there are any special settings required, other than closing the Window when the program terminates.

We are using the PCAnywhere on xxx's terminal, so I don't think the PCAnywhere shortcut is required on that workstation.

  I am trying to Print the Survey information in the CDS49 system, but I get an error:

"Estdoc table is damage" Then it goes back to the prompt for Ctrl + C, I have to then go back into the system. Is there a 'tools' option I can use to fix this error?

In the CDS49 choose Reports, PrivRestore. This restores the temporary report tables such as Estdoc, which can get damaged if there is a problem printing, and should correct the problem.

  I was inputting the customer address and there are some companies that i have to put a second address. Invoice could get billed to address#1 or to Address #2. We were imputing the second address on the right side second Box. But it's not taking as a second address it's combining both Addresses. Can you please tell me were do i enter the second address.

On Page 1 of the Customer screen, the 6 INV ADDRESS fields are for the Invoice Address. On Page 3 of the Customer screen the ADDRESS2 fields are used for information and/or a second Invoice Address.
For Repair Invoices *only* INV ADDRESS is used.
For Storage & Handling Invoices INV ADDRESS or ADDRESS2 is used depending
on whether ADDRESS (on Page 4) is set to 1 or 2.
For Manual Invoices INV ADDRESS or ADDRESS2 is used depending on whether
ADDRESS (on Manual Invoice Screen) is set to 1 or 2.

  Can we input estimates using ISO CEDEX codes?

You can do this in the component screen by pressing Insert and filling in the Cedex Code in the COMPONENT field and then press F7 in each of the other fields. The F7 key copies what is on the record that was present before inserting the new record. Test it by doing it on one component and then using that component on an estimate. Don't forget that after adding a component record you need to run the Prep option on the Lookup Sub Menu before the component is available for use in estimates.

If you have estimates already in the system, we cannot replace your code set. You would need to add another code using the Cedex Code for every code you have.

  Is there any way to get our address and phone as well as the customers address on the monthly storage bill? It's not a big deal I just thought there might be a setting in Set-up or something?

To put your address on the Invoices it must be set-up in the Set-up Screen (Maint, Set-up) in the ADDRESS fields under the COMPANY Names. You should also have the HEADED INVS & ESTS set to N, if you want the Company Name and Address to appear on the Invoices.